Fault Tracing
ANCA Motion DS619-0-00-0019 - Rev 0 151
Encoder Adjusted Amplitude Low - Motor E0215
The magnitude of the adjusted signals for the motor analogue encoder is too low. Incorrect
gain and/or offset values have been configured.
Encoder Adjusted Amplitude High - Motor E0216
The magnitude of the adjusted signals for the motor analogue encoder is too high. Incorrect
gain and/or offset values have been configured.
Control Unit Synchronization Bit Toggle Missing E0220
This error indicates a problem with communications between the EtherCAT Master (eg. CNC)
and the drive. Please contact ANCA Motion for support.
Distributed Clocks Error E0221
This error indicates a problem with communications between the EtherCAT Master (eg. CNC)
and the drive. Please contact ANCA Motion for support.
Encoder Adjusted Amplitude Low - External E0227
The magnitude of the adjusted signals for the external analogue encoder is too low. Incorrect
gain and/or offset values have been configured.
Encoder Adjusted Amplitude High - External E0228
The magnitude of the adjusted signals for the external analogue encoder is too high. Incorrect
gain and/or offset values have been configured.
DC Bus Voltage High E0302
DC bus voltage in the power stage exceeded the hardware maximum limit. Possible causes
for this error are:
1. Regenerative load is outside the specification for the drive.
2. Mains supply voltage is too high.
3. Regeneration resistor or drive is faulty. Please contact ANCA Motion for support.
DC Bus Voltage Low E0303
DC bus voltage in the power stage is below the hardware minimum limit. Possible causes for
this error are:
1. Mains supply is not connected.
2. Connector for external inductor, missing inductor or link across P1, P2.
3. Mains supply voltage is too low.
4. Power requirements for the application are outside the specification for the drive.
5. Drive is faulty.
Please contact ANCA Motion for support.