Fault Tracing
ANCA Motion DS619-0-00-0019 - Rev 0 149
2. Encoder cable is disconnected.
3. Encoder cable is wired incorrectly.
4. Encoder is not analogue.
5. Encoder is not outputting the correct voltage.
6. Encoder is faulty.
7. Drive is faulty. Please contact ANCA Motion for support.
Encoder Amplitude High - External E0028
The magnitude of the signals coming from the external analogue encoder is too high. Possible
causes for this error are:
1. Encoder cable is wired incorrectly.
2. Encoder is not analogue.
3. Encoder is not outputting the correct voltage.
4. Encoder is faulty.
5. Drive is faulty. Please contact ANCA Motion for support.
Excess Difference in Position Feedback E0033
The difference between motor and external feedback is greater than the configured threshold.
Possible causes for this error are:
1. Incorrect encoder line count.
2. Incorrect gear box ratio and/or feed constant.
3. Faulty drive mechanism (eg. loss coupling).
4. Faulty encoder.
5. Fault drive. Please contact ANCA Motion for support.
Variable Torque Limit Error E0080
Configuration of the variable torque limit is invalid. The minimum torque limit is configured
larger than the maximum torque limit.
Drive Not Configured E0100
The drive has been enabled before being configured
Amplifier Temperature Sensor Error - High E0101
Drive power stage temperature sensor is reading a value higher than the drive's sensor
operating range. Drive is faulty. Please contact ANCA Motion for support.
Amplifier Temperature Sensor Error - Low E0102
Drive power stage temperature sensor is reading a value lower than the drive's sensor
operating range. Drive is faulty. Please contact ANCA Motion for support.
Amplifier Temperature High Warning W0103
The drive amplifier (power stage) temperature exceeds the hardware's warning level. Possible
causes for this error are:
1. Operating environment is outside specification.
2. Drive ventilation is insufficient.